My Company Rules

Shedmate is a very flexible program that can adapt to multiple companies and workflows.

Some organizations will work with Universal Beams, while others with only Cold Formed Profiles. Some will do mezzanines, awnings and welded connections, while others will stick with the basics and have specific roof slopes due to brackets.

To extract the best from Shedmate for your organization, we need to understand what and how you do things. The video below explains some of the different company rules we can set up for you in your onboarding process.

To help you while setting up your company rules, please copy and paste the table below, fill out with your company rules and send it via e-mail to our support team at support@shedmate.com.au

Description
Yes/No
Range

Maximum Shed Width

Yes

20m

Maximum Height

Yes

6m

Maximum Length

Yes

Maximum Length Bay Size

Yes

Maximum Width Bay Size

Yes

Roof Types

Yes

Gable, Skillion

Roof Slope Gable

Yes

12, 15, 18, 25

Roof Slope Skillion

Yes

3, 5, 9, 12

Colours

Yes

Zinc, Colorbond Range

Sliding Doors (Panels)

Yes

Roller Doors

Yes

B&D / Steeline Range

Roller Door/ PanelLift Motors/Chain

Yes

Sectional Door (Panel lift)

Yes

Awnings

Yes

Mezzanines

Yes

Flooring: Yellow Tongue, Blue Tongue, Red Tongue

Windows

Yes

Ultra Silver Frames 1200x900

Bay Openings

Yes

Personal Access Door

Yes

810, 920 wide

Glass Doors

Yes

1800(W) x 2100(H) only

Spinaways

Yes

300mm

Skylights

Yes

Clear, Grey, Opal, Cream, Bronze

Wall Skylights

Yes

Down Pipes

Yes

Round PVC / Rectangular Steel Down Pipes

Internal Walls

Yes

Concrete Slabs

Yes

Footings

Yes

Round

Concrete Apron

Yes

Insulation on Roof

Yes

Builder Blanket 55mm / Etherm / Air Cell / Shed Liner / Builder Blanket 75mm / Sisalation / Air Cell ( Insulwhite, Insulshed, Insulbreak, Insuliner, Glareshield, Retroshield, Permiwall)

Insulation on Walls

Yes

Builder Blanket 55mm / Etherm / Air Cell / Shed Liner / Builder Blanket 75mm / Sisalation / Air Cell ( Insulwhite, Insulshed, Insulbreak, Insuliner, Glareshield, Retroshield, Permiwall)

Gutters

Yes

Square Fascia / Internal Gutter (Box Gutter)

Cladding Type

Yes

Corrugated, Trimdek, Uniclad, Rib, O.P. Panel, Hi-Deck, Low Profile, K-Panel

Purlins and Girt Frames

Yes

Top Hats / C-Section / Z

Knee Bracings

Yes

Fly bracings

Yes

Verming Proofing

Yes

Vermaseal

Ridge Vent

Yes

Pergolas

Yes

Web Trusses

Yes

Structural Frames

Yes

Cold Formed Section, SHS, RHS, UB, PFCs, Including Double Up Columns and Rafters.

Force Same Frame for Columns and Rafters

Yes

Bridging (Supporting) Beams

Yes

Double Columns

Yes

Double Bridging Beams

Yes

Double Rafters

Yes

Allow Eave Overhangs

Yes

Slipt Girts and Purlins

Yes

Purlin and Girt Bridgings

Yes

Force Same Frame for Girts and Purlins

Yes

Last updated